Sign In | Join Free | My burrillandco.com
Home > Dual Channel Potentiostat Bipotentiostat >

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Wuhan Corrtest Instruments Corp., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test from wholesalers
     
    Buy cheap Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test from wholesalers
    • Buy cheap Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test from wholesalers
    • Buy cheap Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test from wholesalers

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Ask Lasest Price
    Brand Name : Corrtest
    Model Number : CS2350M
    Certification : CE, ISO9001
    Price : Negotiable
    Payment Terms : T/T, D/P
    Supply Ability : 1000set/year
    Delivery Time : 5-10 working days
    • Product Details
    • Company Profile

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    EIS bipotentiostat CS2350M hydrogen permeation test has two sets of built-in independent potentiostat /galvanostat. The two channels can jointly complete experiment of RRDE and hydrogen permeation test. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. EIS bipotentiostat CS2350M hydrogen permeation test

    is the real double-channel potentiostat. Experiments can also be conducted at the same time in each channel(see below picture: the 2 channels connect to 2 coin cells).It uses Ethernet connection. EIS module is included in both channels. Each set provides full electrochemical techniques including EIS.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Applications of EIS bipotentiostat CS2350M

    EIS bipotentiostat CS2350M can do all that a single-channel potentiostat can, as there are 2 sets potentiostat/galvanostat inside of CS2350M eis Bipotentiostat/Bigalvanostat. EIS bipotentiostat CS2350M can be used in the following applications, and can do testing on two samples at the same time.


    (1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

    (2) Electrocatalysis such as Oxygen reduction reaction (ORR), OER, HER, CO2 reduction.
    (3) Li-ion battery, solar cell, fuel cell, supercapacitor, advanced function materials, sensor, etc
    (4) Corrosion behavior of metals, and anti-corrosion evaluation

    (5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.


    One of the typical applications of EIS bipotentiostat CS2350M

    Hydrogen permeation Test (HDT)

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Photo of EIS bipotentiostat CS2350M hydrogen permeation test setup


    CS2350M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Hydrogen permeation test principle

    The electrochemical method proposed by Devanathan-Stachurski to measure the diffusion rate of atomic hydrogen in metals.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Diagram of EIS bipotentiostat CS2350M hydrogen permeation test


    The device is composed of two electrolytic cells. The left one is hydrogen elimination chamber (anode chamber). A constant potential is applied on the anode surface of the specimen. The hydrogen atoms diffused from the cathode surface are oxidized on the anode surface.The right cell is the hydrogen charging chamber (cathode chamber). During hydrogen charging, the cathode current is applied on the cathode surface.


    Specifications of EIS bipotentiostat CS2350M hydrogen permeation test

    Specifications
    Support 2-, 3- or 4-electrode systemInterface: Ethernet
    Potential control range: Primary Channel: ±10V second Channel: ±10VCurrent control range: ±1A in each channel
    Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
    Potential resolution: 10μV (>100Hz), 3μV (<10Hz)Current sensitivity:1pA
    Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
    Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
    Maximum current output: ±1A in each channelCV and LSV scan rate: 0.001mV~10,000V/s
    CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
    Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
    DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
    DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
    IMP frequency: 10μHz~1MHzLow-pass filters: Covering 8-decade
    Potential and current range: AutomaticWeight / Measurements: 6.5kg,36 x 30 x16cm
    Operating System: Windows 7/8/10/11
    Electrochemical Impedance Spectroscopy (EIS)
    Signal generator
    Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
    DC Bias: -10~+10VOutput impedance:50Ω
    Waveform: sine wave, triangular wave and square waveWave distortion:<1%
    Scanning mode: logarithmic/linear, increase/decrease
    Signal analyzer
    Integral time: minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
    Measurement delay:0~105s
    DC offset compensation
    Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
    Bandwidth: 8-decade frequency range, automatic and manual setting

    Techniques- EIS bipotentiostat CS2350M hydrogen permeation test

    Bipotentiostat

    • Hydrogen permeation(Diffusion) Test (HDT)
    • Rotating Ring Disk Electrode(RRDE)
    • Faradaic efficiencyTest(FE)

    Stable polarization

    • Open Circuit Potential (OCP)
    • Potentiostatic (I-T curve)
    • Galvanostatic
    • Potentiodynamic (Tafel plot)
    • Galvanodynamic (DGP)

    Transient Polarization

    • Multi Potential Steps
    • Multi Current Steps
    • Potential Stair-Step (VSTEP)
    • Galvanic Stair-Step (ISTEP)

    Chrono Method

    • Chronopotentiometry (CP)
    • Chronoamperametry (CA)
    • Chronocaulometry (CC)

    Voltammetry

    • Linear Sweep Voltammetry (LSV)
    • Cylic Voltammetry (CV)
    • Staircase Voltammetry (SCV)
    • Square Wave Voltammetry (SWV)
    • Differential Pulse Voltammetry (DPV)
    • Normal Pulse Voltammetry (NPV)#
    • Differential Normal Pulse Voltammetry (DNPV)
    • AC Voltammetry (ACV)
    • 2nd harmonic AC Voltammetry (SHACV)
    • Fourier Transform AC Voltammetry (FTACV)

    Electrochemical Impedance Spectroscopy (EIS)

    • EIS vs Frequency (Nyquist, Bode)
    • Galvanostatic EIS
    • EIS vs Potential (IMPE)(Mott-Schottky)
    • EIS vs Time (IMPT)
    • Galvanostatic EIS vs Time

    Corrosion Measurements

    • Cyclic polarization curve (CPP)
    • Linear polarization curve (LPR)
    • Electrochemical Potentiokinetic Reactivation (EPR)
    • Electrochemical Noise (EN)
    • Zero resistance Ammeter (ZRA)

    Battery test

    • Battery Charge and Discharge
    • Galvanostatic Charge and Discharge (GCD)
    • Potentiostatic Charging and Discharging (PCD)
    • Potentiostatic Intermittent Titration Technique (PITT)
    • Galvanostatic Intermittent Titration Technique (GITT)

    Amperometric

    • Differential Pulse Amperometry (DPA)
    • Double Differential Pulse Amperometry (DDPA)
    • Triple Pulse Amperometry (TPA)
    • Integrated Pulse Amperometric Detection (IPAD)

    Stripping Voltammetry

    • Potentiostatic Stripping
    • Linear Stripping
    • Staircase Stripping
    • Square Wave Stripping
    • Differential Pulse Voltammetry Stripping
    • Normal Pulse Voltammetry Stripping
    • Differential Normal Pulse Voltammetry Stripping

    Extensions

    · Data Logger

    · Electrochemical Stripping/ Deposition

    · Bulk Eletrolysis with Coulometry (BE)

    · Rs Measurement


    Application

    Corrosion: Corrtest potentiostats incl. EIS bipotentiostat CS2350M have all the electrochemical techniques for corrosion measurement such as OCP, polarization curve (potentiodynamic), EIS, Cyclic polarization CPP (passivation curve), Electrochemical Potentiokinetic Reactivation (EPR), Hydrogen diffusion test, ZRA, Electrochemical noise, etc. It can be used to study metal corrosion mechanism and corrosion resistance, and evaluate the coating durability and sacrificial anode current efficiency. It can also be used for rapid screening of corrosion inhibitors, fungicides, etc.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Left: Polarization curves of Ti-alloy& stainless steel in 3%NaCl solution Right: EN of low-carbon steel in 0.05mol/LCl+0.1mol/LNaHCO3

    EIS bipotentiostat CS2350M uses correlation integral algorithm and dual-channel over- sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc)


    Salt spray aging test of high impedance coating

    Energy

    With techniques LSV, CV, galvanostatic charge and discharge (GCD), Constant potential/ current EIS, and precise IR compensation circuit, Corrtest potentiostats incl. EIS bipotentiostat CS2350M are widely used in supercapacitor, Li-ion batteries, sodium-ion batteries, fuel cell, Li-S batteries, solar cell, solid-state batteries, flow batteries, metal-air batteries etc. It is an excellent scientific tool for researchers in the fields of energy and materials.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Salt spray aging test of high impedance coating CV curve of PPy supercapacitor in 0.5 mol/L H2SO4 solution


    Electroanalysis

    Corrtest potentiostat incl. EIS bipotentiostat CS2350M includes all the voltammetric methods such as NPV, DNPV, SWV, ACV, and can be used for fast analysis of the trace elements in the solution. Voltammetry stripping methods can do the Quantitative analysis according to the stripping peak current.

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    Stripping voltametric curves in solution of different Pb2+, Cd 2+,Zn2+ concentration


    Electro-catalysisTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    ● Corrtest potentiostat incl. EIS bipotentiostat CS2350M can measure the half-wave potential (ORR), overpotential (HER, OER) of the catalyst, and has the function of peak power density and energy density calculation.


    ● Long-term cyclic measurement for ORR, OER, HER,

    CO2RR by techniques such as cyclic voltammetry,

    potentiostatic, galvanostatic. Faraday efficiency can be

    measured with a bipotentiostat.


    LSV curve of catalysts in alkaline solution

    Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

    ● Maximum current can be 20A and compliance voltage can be 30V, and with IR compensation technique,

    Corrtest potentiostat can precisely measure the overpotential of the electrode, which is a big advantage in electrocatalysis field.


    Quality Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuhan Corrtest Instruments Corp., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)